Detection method of tubing coupling based on magnetic field induction
DOI:
https://doi.org/10.63313/AERpc.9011Keywords:
Snubbing Operation, Coupling Detection, Magnetic Testing Method, Finite Ele- Ment AnalysisAbstract
The inspection of tubing coupling is a key part to ensure the safety of snub-bing operation, To realize the accurate identification of tubing and coupling, Studied a magnetic detection method, Accurate identification of coupling by capturing the difference in magnetic field strength between the surface of the oil pipe and the coupling, This paper uses COMSOL software to establish a finite element simulation model of the pipe coupling detection device. Through simu-lation calculations, the effects of the spacing between magnetic materials, per-manent magnet strength, pipe eccentricity, and coupling defects on the detec-tion performance are studied. The influence patterns of different factors on the detection results are obtained, and finally, experiments are conducted to verify the feasibility of the method.
References
[1] Dost, Y.,Apaydın,et al.(2012).Non-destructive testing of Bosphorus Bridges. RILEM Bookseries,6: 819-825. doi: 10.1007/978-94-007-0723-8_117
[2] F.I. Al-Naemi,J.P. Hall,A.J. Moses.(2006). FEM modelling techniques of magnetic flux leak-age-type NDT for ferromagnetic plate inspections. Journal of Magnetism and Magnet-ic Mate-rials,304(2): e790-e793. doi: 10.1016/j.jmmm.2006.02.225
[3] Jomdecha, C.,Prateepasen,et al.(2009). Design of modified electromagnetic main-flux for steel wire rope inspection.[J]. NDT and E International,42(1): 77-83. doi: 10.1016/j.ndteint.2007.10.006
[4] Ni, XH ,et al.(2014). Research and Application Survey of Coupling Alarm in Pressure Opera-tion. INTERNATIONAL CONFERENCE MACHINERY, ELECTRONICS AND CONTROL SIMULATION,614: 672-675. doi: 10.4028/www.scientific.net/AMM.614.672
[5] Qun LEI,Dingwei WENG,Jianhui LUO. (2019). Achievements and future work of oil and gas production engineering of CNPC. Petroleum Exploration and Development,46(1): 145-152. doi: 10.1016/S1876-3804(19)30014-X
[6] Qun LEI, Yiliang LI, Tao LI, Hui LI, Baoshan GUAN, Guoqiang BI, et al.(2020). Technical status and development direction of workover operation of PetroChina. Petroleum Ex-ploration and Development,47: 161-170. doi:10.11698/PED.2020.01.15
[7] Sorabh,Gupta, A.,et al.(2016). Finite Element Modeling of Magnetic Flux Leakage from Metal Loss Defects in Steel Pipeline(Article). Journal of Failure Analysis and Preven-tion,16(2): 316-323. doi: 10.1007/s11668-016-0073-6
[8] Shi, MJ,et al. (2018). Study on detection methods of residual wall thickness for process pipe-line corrosion in oil and gas gathering and transportation station(Article). Journal of Magnet-ics,23(2): 142-151. doi: 10.4283/JMAG.2018.23.2.142
[9] Wang, YK ,et al.(2019). Research on intelligent alarm method of coupling about snubbing operation in oil and gas field(Conference Paper). IOP Conference Series: Earth and Envi-ron-mental Science,252(5): 052114. doi: 10.1088/1755-1315/252/5/052114
[10] Zhong, GX,et al.(2011). The Structure and Technical Parameters Analysis of Snubbing Unit. ADVANCED MANUFACTURING SYSTEMS,339: 566-570. doi: 10.4028/www.scientific.net/AMR.339.566
Downloads
Published
Issue
Section
License
Copyright (c) 2025 by author(s) and Erytis Publishing Limited.